Caution, Vent information and diagrams, Warning – Quadra-Fire QVI-30FB-S User Manual

Page 10: C. measuring standards, B. horizontal venting, A. vent table key

Advertising
background image

Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09

10

CAUTION

ALL vent specifi cations MUST be followed.

• This product is tested and listed to these specifi cations.

• Appliance performance will suffer if specifi cations are not

followed.

Figure 5.1

C. Measuring Standards

Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:

• Vertical terminations are measured to top of chimney.

Fire Hazard.

Explosion Risk.

Asphyxiation Risk.

Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid fuel or
gas burning appliance.

• May impair safe operation of this appliance

or other appliances connected to the fl ue.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

B. Horizontal Venting

Horizontal venting is NOT allowed.

5

5

Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in
the vent diagrams.

Symbol

Description

V

MIN

Minimum Vertical Run Length 14 ft.

V

MAX

Maximum Vertical Run Length 50 ft.

WARNING

TERMINATION

CAP

ADAPTOR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM

50 FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

EXHAUST COLLAR

INLET AIR COLLAR

Note: To achieve optimum
per formance of inser t,
minimize or avoid bends
in exhaust vent pipe.