Caution, Warning, B. junction box installation – Quadra-Fire QVI-30FB-S User Manual

Page 18: C. installation for fan (optional)

Advertising
background image

Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09

18

B. Junction Box Installation

Figure 9.2 Junction box installation

JUNCTION

BOX

SIDEWALL

FEED PLUG

THROUGH HOLE

INSERT STRAIN RELIEF

AROUND CORD IN THIS END

FROM OUTSIDE OF UNIT

SCREW

PROVIDED

Optional Accessories

Connecting the electrical junction box is required if using
a blower or remote.

• Plug the cord into a convenient outlet.

• An electrician may install an outlet box inside the

fi replace. Place the outlet in the lower, back corner of
the fi replace.

• Must use cord supplied.

C. Installation for Fan (Optional)

On units already installed removal of decorative front,
surround and gas insert is required.

• Detach fl exible liner from back of unit if insert is installed.

• Remove the four screws on the cover plate (see Figure 9.3).

Figure 9.3

FAN

COVER

PLATE

POWER

CORD

GROUND

WIRE

• Bend up the tabs on the base pan (see Figure 9.4).

• Place the blower in between the bend up tabs.

• Install and wire the blower per instruction shipped with

the fan.

• The ground wire of the fan can clip on the side of the

base pan.

• Reinstall the cover plate back on the unit. Make sure the

fan does not make contact with the back wall to prevent
noise from vibration.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.

• Replace damaged wire with type 105º C rated

wire.

• Wire must have high temperature insulation.

WARNING

Advertising