A. Venting Components

7

7

Installing Vent Pipe and Appliance

The vertical vent termination system installed on this model
includes:

• One 3-foot section stainless steel fl exible pipe (included

with insert).

• One length of 3-inch fl exible vent pipe for combustion air

(included with vent kit).

• Flexible vent pipe for exhaust air (included with vent kit).

• One pipe-to-cap adaptor (included with vent kit).

• One vertical termination cap (included with vent kit).

Figure 7.1

B. Connecting Vent Pipe

Reference instructions in the termination kit.

• Install the 3-inch fl exible vent pipe(s) down through the

chimney.

• Secure the exhaust fl exible vent pipe to the 3 foot section

stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 7.1).

• Use 3 screws to attach either a 4 foot or 30 foot section

of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1). NOTE: The collar slide plate may be
removed from appliance to aid installation.

• Seal opening between fl ex vent and chimney just above

insert. Unfaced fi berglass insulation may be used for this
purpose.

CAUTION

Sharp Edges
• Wear protective gloves and safety

glasses during installation.

TERMINATION

CAP

ADAPTOR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM

50 FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

EXHAUST COLLAR

INLET AIR COLLAR

Note: To achieve optimum
per formance of inser t,
minimize or avoid bends
in exhaust vent pipe.