Figure 1: Installation Diagram (Compact Systems)


Document number: QDC0030PD-11 Page 12 of 40











































Orientation

if multiple

Compact units are












































Condensation
Drain

Power Cord











































100 mm Min












































Wall

500 mm

Min

being installed.

i.e. fan to face out.

Water
Connections

15°


32°

200 mm Min

PTR Valve


NOTE

Front Access

If installing multiple Compact units, the orientation of the tank will need to be at 90° to the normal arrangement
so that the fan points out from the wall rather than along it. This is so that cold air being discharged from one
unit is not drawn in by the one next to it. The space between multiple units should be a minimum of 200mm.

Tank Orientation Diagram for Compact Units