PX502 Tape Library Quick Start Guide

2

Choosing a Location

0

When choosing an installation site for the PX502, consider
the following requirements:
•

Rack Space Requirements

•

Environmental Conditions

Rack Space Requirements

0

Table 1

contains the rack requirements for the PX502 tape

library.

Table 1 Rack Requirements

Environmental Conditions

0

The installation site must have the following environmental
conditions:
•

Humidity: 20%-80% non-condensing

•

Temperature: 10°C-35°C (50°F-95°F)

•

Altitude: -500 to 10,000 feet (-152 to 3048 meters)

These environmental conditions apply when the PX502 tape
library is in operation.

Preparing for the Installation

0

Before you begin the installation procedure in this section,
make the following preparations as described in this
section:
•

Providing Necessary Tools

•

Taking ESD Precautions

Dimensions

PX502

Depth

31 in (78.7 cm)

Width

19 in (48.3 cm)

Height

6.75 in (17 cm), 4U

Weight

52 lbs (23.6 kg)

Air Clearance

Open 4 in (10 cm) behind unit

for proper air flow

N

OTE

: For additional specifications, refer to the

Quantum PX500 Series User’s Guide (PN 81-
81290)

Providing Necessary Tools

0

Provide the following tools for unpacking and installing the
PX502 tape library:
•

#1 PHILLIPS® screwdriver

•

#2 PHILLIPS screwdriver

•

#1 flat blade screwdriver

•

Allen wrench (2.5mm and 3mm) included in accessory
kit

•

Antistatic wrist strap included in accessory kit

Taking ESD Precautions

0

Some components within the PX502 tape library contain
static-sensitive parts. To avoid damaging these parts while
performing installation procedures, always observe the
following precautions:
•

Keep the PX502 turned off during all installation
procedures.

•

Use an antistatic wrist strap (included in the accessory
kit).

•

Keep static-sensitive parts in their original shipping
containers until ready for installation. Look for the ESD
sticker to identify static sensitive parts.

•

Avoid touching connectors and other components.

Unpacking the PX502 Tape Library

0

This section explains how to unpack the PX502 tape library
and move it to its final installation location.

N

OTE

: Dry climates and cold-weather heating

environments have lower relative humidity and
are more likely to produce static electricity.

N

OTE

: Inspect the outer library packaging for damage. If

there is any damage evident on the library
packaging, do not continue with the installation
and contact Quantum customer support.