Troubleshooting – Quadra-Fire 1100-I User Manual

Page 17

Advertising
background image

1. PLUG IN INSERT, NO RESPONSE

A. Check the power supply for 120 volts AC.
B. Check the fuse in the junction box (7 amp, 120 volt fuse

AGC-7).

C. Check snap disc #3 (unplug insert before checking). Push

reset on snap disc #3.

D. Control box (consult your dealer).

2. CALL LIGHT ON, NO FIRE, NO FUEL IN FIREPOT

A. Check the hopper for fuel, sawdust or bridging of pellets

in the bottom of the hopper. If the hopper is low on fuel,
vacuum can be lost through the hopper.
NOTE: Sometimes there might still be fuel in the
hopper. If so, continue to check the areas below.

B. Make sure that the exhaust blower is operating.
C. Check the venting system for obstructions that might

cause restrictions, which would cause the vacuum safety
switch to shut off the auger.

D. Check the heat exchanger system for high ash content If

buildup is present, clean the heat exchanger system.

E. Push the reset button, and try to light the insert again.

3. CALL LIGHT ON, NO FIRE, PARTIALLY-BURNED

FUEL IN THE FIREPOT

A. Clean the firepot. Check that the igniter hole is clean and

the cleanout plate is tightly in place.

B. Inspect the thermocouple and cover for the following:

1. The cover needs to be making contact with the end of

the thermocouple.

2. The thermocouple and the cover should extend

approximately 1”(25mm) into the firepot for accurate
temperature reading.

3. Push the reset button. When the thermocouple reaches

200°F (93°C) the GREEN LIGHT will come on, and
at 1000°F (538°C) the RED LIGHT will come on.
NOTE: If the lights fail to come on after the fire
starts, the thermocouple may be faulty.

C. If the thermocouple appears good, the control box may be

the problem (consult your dealer).

4. CALL LIGHT ON, NO FIRE, UNBURNED PELLETS IN

FIREPOT

A. Clean the firepot (possibly a bridging problem at the ignition

hole, located at the bottom of the firepot).

B. If the fire does not start, push the reset button.
C. Check the igniter to see that it comes on. If it does not turn

on, check the following:

1. Check the connections under the firepot. (Ceramic wire

nuts must be used to withstand the heat produced by
the firepot.)

2. Make sure that the igniter is property installed in the

igniter bracket. It should fit tightly, and be centered in
the igniter hole.

3. Inspect the igniter. Replace if damaged.

TROUBLESHOOTING

CAUTION: UNPLUG STOVE BEFORE SERVICING

Page 17

5. SLOW OR SMOKY START-UP

A. Clean the firepot. Check the firepot gasket for a good

seal between the firepot and the firebox floor.

B. Check the combustion blower (make sure that it is

starting when the thermostat calls for heat).

C. Visually check the cleanliness of the firebox, the heat

exchangers and the venting system.

D. The feed rate may be too high. If necessary, adjust with

the fuel adjustment rod located in the hopper.

E. Due to elevation, the air adjusting plate may need to be

adjusted to get the right air to fuel ratio.

6. STOVE RUNS FOR 10 MINUTES, THEN STOPS

FEEDING FUEL

A. Inspect the thermocouple and the cover.

1. The cover needs to make contact with the end of the

thermocouple.

2. The thermocouple and the cover should extend

approximately 1” (25mm) into the firepot.

3. Push the reset button. The thermocouple test lights

located on the control box will automatically turn on;
when the thermocouple reaches 200°F (93°C) the
GREEN LIGHT comes on, and at 1000°F (538°C)
the RED LIGHT comes on. If they fail to turn on
after the fire starts, the thermocouple may need
replacement.

4. Check the control box (consult dealer).

7. FEED SYSTEM FAILS TO START

A. Make sure that the front door to the firebox is closed tightly.
B. Check to make sure that the exhaust blower is coming on

and working.

C. Check the heat exchanger and the venting system for

obstructions or heavy ash buildup.

D. The vacuum switch hose may be plugged.

1. Pull the hose off and blow through it to make sure it is

clear.

NOTE: Unplug insert from power outlet first.

E. Downdrafts or poor venting systems that do not follow

manufacturer’s recommendations can also cause this
problem.

F. Check the hopper and the feed system for blockage.