C. Vent Termination

For Horizontal Terminations - To attach and secure the
termination to the last section of horizontal vent:

• Rotate and interlock the ends as described at the begin-

ning of the Installing Vent Components section.

• The termination kit should pass through the wall firestops

from the exterior of the building.

• Adjust the termination cap to its final exterior position on

the building.

WARNING: THE TERMINATION CAP MUST BE
POSITIONED SO THAT THE ARROW IS
POINTING UP.

For trapezoidal cap termination kits:

• Using screws secure the cap to the exterior wall through

the flanges in the cap.

Figure 25. Trapezoid Termination Cap

!

WARNING: VENTING TERMINALS SHALL
NOT BE RECESSED INTO A WALL OR SID-

ING. VENT TERMINATION CLEARANCES MUST
BE FOLLOWED TO AVOID FIRE DANGER. SEE
THE VENT TERMINATION DIAGRAM FOR VENT
TERMINATION CLEARANCES DIAGRAM ON FOL-
LOWING PAGE.

7 1/4"

(184mm)