Step 8. wiring the fireplace – Quadra-Fire Gas Fireplace QV-ST User Manual

Page 29

Advertising
background image

29

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed
electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR WALL
SWITCH OR THE APPLIANCE WILL MALFUNC-
TION AND THE VALVE WILL BE DESTROYED
.

!

Figure 31. Standing Pilot Ignition Wiring Diagram

Figure 32. Fan Wiring Diagram

Optional Accessories

Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.

BLACK S2

ON

OFF

ON/OFF

SWITCH

WHITE T2

RED T1

THERMOPILE

GAS VALUE

BLACK S1

3/16” PIGGYBACK CONNECTOR

THERMOCOUPLE

REMOTE SWITCH

PIGTAIL

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

FAN

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

JUNCTION BOX

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.

O

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

Advertising