Advantys™ distributed i/o, ftb splitter boxes, Ip 67 monobloc i/o splitter boxes for fieldbuses, Presentation, functions – Quantum Instruments Splitter Boxes User Manual

Page 14: Advantys, Distributed i/o, ftb splitter boxes

Advertising
background image

14

Presentation,
functions

0

IP 67 monobloc I/O splitter boxes
for fieldbuses

0

Advantys™

Distributed I/O, FTB splitter boxes

Presentation

To meet the needs of machine manufacturers and users, automation system
architectures are becoming decentralized, while offering performances comparable
to those obtained with a centralized structure.
Advantys FTB IP 67 monobloc I/O splitter boxes enable sensors and actuators to be
connected in distributed automation systems using pre-assembled cables, thus
reducing wiring time and costs, whilst at the same time increasing the operational
availability of the installation.

These IP 67 protected splitter boxes can also be used within processes or machines
in harsh environments (splashing water, oil, dust, etc.). For difficult environments
(welding shops etc.), a range of Advantys FTB splitter boxes with a metal housing is
available.

Advantys FTB splitter boxes allow distributed connection of sensors and actuators
on machines via a fieldbus. They communicate on different buses such as:
CANopen, DeviceNet, Profibus-DP and InterBus.
Sensors and actuators are connected by means of standard M12 connectors.

Configuration and parametering of the Advantys FTB splitter boxes is carried out
using configuration files (e.g.: .eds files for CANopen):
b either directly within the software workshop of the PLC used,
b or by using a SyCon type configurator (refer to our Modicon

®

Premium

PLC

automation platform catalog).

Advantys FTB splitter boxes are available with different input (c 24 V IEC type 2)
and output (transistor c 24 V/1.6 A) configurations:
b Mixed 8 input and 8 output splitter boxes, allowing connection of either 8 sensors
and 8 actuators or 8 actuators with integrated diagnostics function.
b Mixed 12 input and 4 output splitter boxes, allowing connection of either
12 sensors and 4 actuators or 4 sensors and 4 actuators with integrated diagnostics
function.
b 16 input splitter boxes allowing connection of either 16 sensors or 8 sensors with
integrated diagnostics function.
b Mixed 16 input or output splitter boxes, configurable per channel, allowing all
possible combinations: 16 inputs, 15 inputs/1 output, 14 inputs/2 outputs, to .,
16 outputs.

Functions

Selection of signal type per channel
b Each M12, 5-pin connector on Advantys FTB splitter boxes allows the connection
of 2 signals. Depending on the type of splitter box, these can be:
v 1 sensor input signal,
v 1 diagnostic input signal,
v 1 actuator output signal.

Signal type, depending on splitter box selected:

FTB

1pp16E

1pp08E08S 1pp12E04S

1pp16C

1Dp08E08C

M12

Contact 4 Input

Output

0 to 3: Input
4 to 7: Output

Input
Output

Input
Output

Contact 2 Input

Diagnostic

Input
Diagnostic

Input
Diagnostic

Input
Output
Diagnostic

Input
Diagnostic

Note: either a normally open (N/O) or a normally closed (N/C) contact can be chosen for each
input signal.

Description, configuration:
pages 18 , 21, 24,

Characteristics:
pages 26, 27

References:
pages 28 - 30

Dimensions:
pages 31 - 33