Configuring termination resistors, Testing db-9 serial ports in hyperterminal, Figure 41 - rs-422/485 jumper settings – Quatech HSU-300 User Manual

Page 36: Table 5 - rs-422/485 termination jumpers

Advertising
background image

Quatech Freedom USB Adapter User’s Manual

Making external connections

All ports

RS-422/485 signal description

DB-9

Auxiliary Input (AuxIn–)

9

Configuring termination resistors

Factory installed resistors allow for Freedom USB-200/300 signal line

termination in compliance with RS-422 and RS-485 standards. You

can select or remove the desired termination by configuring the
associated jumper for each port. The following Figure shows the

factory default configuration: no termination.

Figure 41 - RS-422/485 jumper settings

2
1

4
3

2
1

4
3

Factory Default = pins 3 & 4

(no termination)

J3

J2

CN1

Jumpers J2 through J5 (DSU) or J2 through J9 (QSU/ESU/HSU)
allow the following selections:

RS-422 (100 ohm) termination

RS-485 (120 ohm) termination
no termination

For normal operations over shorter distances or when using a

termination in the connecting cable, use the default setting. For
communications over great distances or if termination via the

connecting cable is not feasible, configure the jumpers for the desired

termination as follows.

RS-422 termination, jumper pins 1 and 3
RS-485 termination, jumper pins 2 and 4

Only terminate signals that are present in the cable. If the auxiliary

input is not used and is not needed or wired in the cable, do not select

the auxiliary input termination on the board. See the following Table
for termination jumper assignments.

Note: To access the USB

adapter directly, remove the

four screws on the bottom of
the box and open the top cover.

Configure each DB-9 connector as shown in the Table below.

Table 5 - RS-422/485 termination jumpers

Receive Data
(pins 4 and 8)

Auxiliary
Input

Rev 2.02 (2/24/2004)

Page 31

Advertising
This manual is related to the following products: