Advice for safety – Tricity Bendix SG211X User Manual

Page 20

Advertising
background image

20

Advice for safety

Gas connections

Before installation ensures that the local

distribution conditions (gas type and

pressure) and the pre-setting of the appliance

are consistent.

This appliance must be installed only in a

room with good ventilation.

This appliance must not connect to a

chimney. It has to be installed and connected

in accordance with the rules in force. Special

attention should be paid to the applicable

disposal concerning ventilation.

The adjacent furniture panels have to be heat

proof or protected by such material.

The adjusting conditions of this appliance are

mentioned on the rating plate.

Connection to gas supply.

Check that the gas flow and the diameter of the

supply pipe is sufficient to supply all the

appliances of the installation.

Check that all connections are tight.

Install an accessible and visible gas tap to

isolate the appliance.

The manufacturer declines any responsibility

for possible damages resulting from an

installation, which doesn't comply with

current legislation.

-

Installation of flues and ventilation for gas

appliances of rated input not exceeding 60

kW (1

st

, 2

nd

and 3

rd

family gases) – Part 2

Specification for installation of ventilation for

gas appliances – BS 5440 Current editions;

-

Gas burning appliances – Part 3 Domestic

cooking appliances burning gas – BS 5386

Current editions;

- Specification for installation of low

pressure gas pipe work of up to 20mm

(R1) in domestic premises (2

nd

family

gas) – BS 6891 Current editions;

-

Pipe threads for tubes and fittings where

pressure-tight joints are made on the

threads (metric dimensions) – BS 21

Current editions;

-

Flexible hoses, end fittings and sockets

for gas burning appliances – BS 669

Current editions;

-

Installation of domestic gas cooking

appliances (1

st

, 2

nd

and 3

rd

family gases)

– BS 6172: 1990 Current editions;

For appliances installed in the Republic of

Ireland please refer to NSAI-Domestic Gas

Installation IS813 Current editions.

Electrical connections

Any electrical work required to install this
cooker should be carried out by a qualified

electrician or competent person, in

accordance with the current regulations.

THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability

should these safety measures not be

observed.

This cooker is designed to be connected to a

230-240V AC 50Hz electrical supply.

Before switching on, make sure the electricity

supply voltage is the same as that indicated on

the cooker rating plate. The rating plate is

located on the oven frame.

Advertising