The cooker is supplied with a 3 core flexible

supply cord incorporating a 13amp plug fitted. In

the event of having to change the fuse, a 13amp

ASTA approved (BS 1362) fuse must be used.

Should the plug need to be replaced for any

reason, the wires in the mains lead are coloured

in accordance with the following code:

Green and Yellow - Earth

Blue - Neutral

Brown - Live

-

Connect the green and yellow (earth) wire to

the terminal in the plug, which is marked
with the letter 'E' or the earth symbol

or

coloured green and yellow.

-

Connect the blue (neutral) wire to the

terminal in the plug, which is marked with

the letter 'N' or coloured black.

-

Connect the brown (live) wire to the terminal

in the plug, which is marked with the letter 'L'

or coloured red.


NOTE:

The earth wire should be about 2 cm

longer than the live and neutral wires.

Upon completion there must be no cut, or stray

strands of wire present and the cord clamp must

be secure over the outer sheath.

A cut off plug inserted into a 13 amp socket is

a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of

safety.

Before connecting check that:

• The plug used for connection is

easily accessible when the
appliance is installed.

Permanent Connection

In the case of a permanent connection, it is

necessary that you install a double pole switch

between the cooker and the electricity supply

(mains), with a minimum gap of 3mm, between

the switch contacts and of a type suitable for

the required load in compliance with the

current electric regulations.

The switch must not break the yellow and

green earth cable at any point.

Ensure that the cooker supply cord does

not come into contact with surfaces with

temperatures higher than 50 deg. C.