Instructions for the installer, Engineer technical data – Tricity Bendix TBG700 User Manual

Page 13

Advertising
background image

13

OVERALL DIMENSIONS

Width:

680 mm

Depth:

510 mm

Height:

72 mm

CUT OUT DIMENSIONS

Width:

560 mm

Depth:

480 mm

Thickness:

30 mm

SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V

~

50 Hz supply, 3 core flexible cable with

non rewireable plug fitted with a 3 amp cartridge fuse

HEAT INPUT

Rear Left Burner

2.0 kW (6826 BTU/HR)

(semi rapid)
Front Right Burner

3.0 kW Natural Gas (10239 BTU/HR)

(rapid)

2.8 kW LPG (9556 BTU/HR)

Rear Right Burner

2.0 kW (6826 BTU/HR)

(semi rapid)
Central Burner

4.0 kW (13652 BTU/HR)

(triple crown)
Front Left Burner

1.0 kW (3413 BTU/HR)

(auxiliary)

APPLIANCE CLASS

3

APPLIANCE CATEGORY

II2H3+

GAS SUPPLY

Natural gas G20 (2H) / 20 mbar

Instructions for the Installer

Engineer technical data

This appliance is manufactured according to the following EEC directives:
2006/95 EEC - 93/68 EEC - 89/336 EEC - 90/396 EEC, current edition.