Commissioning, Pressure testing – Tricity Bendix TBG700 User Manual

Page 26

Advertising
background image

26

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame

setting. To do this, follow the procedure below.

1) Turn the gas tap to the MAX position and ignite.
2) Set the gas tap to the MIN flame position then turn the control knob from MIN

to MAX several times. If the flame is unstable or is extinguished follow the

procedure below.

Procedure:

1) Re-ignite the burner and set to MIN.
2) Remove the control knob.
3) To adjust, use a thin bladed

screwdriver and turn the adjustment

screw (see diagram) until the flame

is steady and does not extinguish,

when the knob is turned from MIN

to MAX. Repeat this procedure for

all burners.

Pressure Testing

The pressure testing must becarried out on the burners.

Proceed as follows:
1) Remove the pan supports and the burner caps and crowns.
2) Fit manometer tube over the injector.
3) Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17

mbar and 25 mbar.

4) Turn off the burner supplies.

Minimum adjustment screw

Advertising