True Fitness 600R User Manual

Page 11

Advertising
background image

















































Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO RPM
READING
600R, 600U

Control Panel













Defective Cables
Defective RPM
Sensor Set

• Disconnect 5PA from 5PB. (Page 19-

20).

• Set meter to check continuity between

pins 2 and 5 of 5PB

• Turn crank and align the magnet with

the sensor

• Is there continuity? If Yes – Replace

Control Panel. If No- continue to next
step.

--------




• Check continuity of RPM Sensor, when

magnet is in alignment with the sensor
there should be continuity, when not
aligned- no continuity. If it does not
respond properly- replace the sensor.

• Check gap on RPM Sensor

• Perform a continuity check on all upper

and lower cables.

• No continuity? – Replace defective

cable.

• Continuity? – Replace RPM Sensor Set.