background image


















































Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO RESISTANCE

750U, 750R

Console Set











Defective Cables





Power Resistance











Brake Harness/

Lower Board

• Remove console bolts to access 7-pin

connector. Do not disconnect console
set.

• Enter DA (resistance) test mode.

(Page 2).

• Press + key to force .7 VDC out of

panel.

• Set meter for DC Volts. Measure

between #2 pin and #4 pin at 7- pin
connector.

• Is .7 VDC present? No- replace console

set. If present, continue on.

--------

• Remove right mast cover and handlebar.

• Measure between the #2and #4 wires at

the 7 –pin connector on the lower board.

• Is .7 VDC present? No- replace cable

for console. If present, continue on.

--------

• DO NOT PEDAL.

• Set meter for resistance. Disconnect 3-

pin connector at the lower control board.
Measure resistance between #1 pin and
#3 pin.

• Resistance should be 10 ohms, +/- 1

ohm.

• If less than 10 Ohms- replace power

resistance. If resistance checks OK,
continue on.

--------

• DO NOT PEDAL.

• Remove main body cover, set meter for

continuity.

• Disconnect brake cable from brake and

lower board.

• Check continuity of all wires in cable.

• Check for cross continuity- this would

indicate multiple shorts in the cable.

• No continuity? Replace Brake cable.

• Yes continuity? Replace lower board.










Note:

You must pedal at least
30 RPM when
performing any voltage
test. You may require the
assistance of another
person when performing
voltage checks.



Multi-meter