True Fitness 600R User Manual

Page 12

Advertising
background image

















































Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO CONTACT
HEART RATE
600R, 600U

Control Panel




















Defective Cables










Defective Handles


• Disconnect 7P6A and 7P6B from

control panel. 600U (Page 19) 600R
(Page 20). Check continuity between
7P6B and handle mounted heart rate
sensor plates of the following:

HRRR and pin 6 of 7P6B
HRRL and pin 5 of 7P6B
HRLR and pin 2 of 7P6B
HRLL and pin 1 of 7P6B

• Is there continuity?

• If yes – replace computer.

• If No- continue to the next step


--------



• Perform a contact and continuity check

on cable 600 12P, 600 12P coils upper
cables and the handle cables.

• Are cables OK? If No- Replace

defective cables. If Yes- continue on to
the next step.


--------


• Remove and carefully check all

connections to the contact plates.

• Reconnect loose connections.

• If connections OK – Replace handles.

















Multi-meter








Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

Page 10