TABLE 2: INSTALLATION DIMENSIONS WITH THERMADOR COOKTOP

Cooktop

CW

CD

OW

OD

SB

BT, Max++

Model No.

Cutout

Cutout

Overall

Overall

Minimum

Backsplash

Width

Depth

Width

Depth

Set Back

Thickness

30” Cooktops: Installed with UCVM30FS

SGS304*

28-15/16

22-1/4

31

23-3/4

1-1/2

3/4

SGSX304*

28-15/16

22-1/4

31

23-3/4

1-1/2

3/4

CET304

28-3/4

22-1/8

31

23-7/8

2-1/2

0

CEP304

28-3/4

22-1/8

31

23-7/8

2-1/2

0

CEM304

28-3/4

22-1/8

31

23-7/8

2-1/2

0

36” Cooktops: Installed with UCVM36FS

SGS365**

34-15/16

22-1/4

37

23-3/4

1-1/2

3/4

SGSX365**

34-15/16

22-1/4

37

23-3/4

1-1/2

3/4

CET365

34-3/4

22-1/8

37

23-7/8

2-1/2

0

CEP365

34-3/4

22-1/8

37

23-7/8

2-1/2

0

CEM365

34-3/4

22-1/8

37

23-7/8

2-1/2

0

Notes

*

Dimension ”SB” is the minimum distance from the leading edge of the counter to the
leading edge of the cutout.

++Dimension ”BT” is the thickness of backsplash that provides 1/4” clearance between vent

and backsplash. Any backsplash with a curved radius where it meets the counter will
require additional clearance. Thicker backsplashes may be used by increasing the counter
and cabinet depths.

All dimensions are in inches and are based upon a standard 24” deep base cabinet
with 25” countertop.

** SGS and SGSX: width in table is at the widest point (center).

Refer to cooktop Installation Instructions for complete information prior to making any
cutouts.

Clearance is provided to allow raising of the hinged main top.