Remote Blower (see Figures 11 and 12 for
further detail):

A. Remove junction box cover and connect

conduit with 5 wires from remote blower.
Hook up wires per Wiring Diagramm.
Fig. 10. Replace junction box cover.

B. Attach duct transition at mounting holes

with sheetmetal screws.

C. Feed remote blower pigtail through strain

relief.

D. Attach strain relief to downdraft near

junction box.

Integral Blower VTN600CV2C (see Figures
10 and 12 for further detail):

E. Connect pigtail to downdraft at 6 pin

connector.

F. Run pigtail wires to juntion box.

G. Inside junction box, connect conduit with

five wires from remote blower. Use a
conduit connector to secure.

Note: Blower and duct transition box may
be installed with duct outlet left, down or
right. Install blower or duct transition in
such a way that access panels can be
removed for service.

Strain Relief

Junction Box

Conduit To

Remote Blower

gure 11 - Remote Blower

Transition

DHZDHR6

Remote Blower

Pigtail

6 Pin Connector

Fig. 11 – Remote Blower