Temco Tool 36TDVN User Manual

Page 24

Advertising
background image

24

TDVN Series Direct Vent Gas Fireplace

20007636

For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustments knob located near the center of the gas
control valve. (Fig. 42)

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figure
43.
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.

Flame Characteristics

Flame & Temperature Adjustment

LO

HI

FP390

FLAME ADJUSTMENT KNOB

11/21/96

Turn

counterclockwise

to increase

flame height

Turn clockwise

to decrease

flame height

Fig. 42 Flame adjustment knob for SIT valve.

FP1229

Pilot flames

11/02

FP1229

Fig. 43 Correct pilot flame appearance.

Advertising