Temco Tool 36TDVN User Manual

Page 34

Advertising
background image

34

TDVN Series Direct Vent Gas Fireplace

20007636

T203

Air shutter

12/12/03 djt

T203

Opening
“A”

Fig. 51 Air shutter opening.

Normal and High

Direct Vent Units - Inputs - Orifice Size - Altitude

BTU/Hr

BTU/Hr

Manifold Pressure Orifice 0 - 2000ft. Altitude in USA

Model

Min. Input

Max. Input

@ Max.

Orifice 0-4500ft Altitude in Canada

33TDVN

12,500

18,000

3.5”w.c.

.079”

33TDVP

12,500

18,000

10.0” w.c.

#56 DMS

36TDVN

13,000

20,000

3.5” w.c.

#45 DMS

36TDVP

14,500

20,000

10.0” w.c.

#55 DMS

39TDVN

15,000

22,000

3.5” w.c.

#43 DMS

39TDVP

16,500

22,000

10.0” w.c.

#54 DMS

Conversion Kits

Change Natural Change Propane

Model

to Propane

to Natural

33TDVN

33DVCKP

--

33TDVP

--

36TDVN

36DVCKP

--

36TDVP

--

39TDVN

39DVCKP

--

39TDVP

--

IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.

Air Shutter Settings

Opening

Model

“A”

33TDVN

1/32” (1.0 mm)

33TDVP

3/8” (9.5mm)

36TDVN

1/32” (1.0 mm)

36TDVP

3/8” (9.5mm)

39TDVN

1/32” (1.0 mm)

39TDVP

3/8” (9.5mm)

NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.

Advertising
This manual is related to the following products: