Tdvn series direct vent gas fireplace, System checks – Temco Tool 36TDVN User Manual

Page 27

Advertising
background image

27

TDVN Series Direct Vent Gas Fireplace

20007636

Defective thermo-generator.

After the pilot has been lit for approximately three minutes,

(Millivolt system)

and only the thermo-generator wire connected to the main

operator head, measure the voltage across TPTH and TP.

This open circuit voltage should be between 500mv and

750mv. Tune the pilot adjustment screw until the mv reading

falls within these parameters. (Counter-clockwise increases

mv reading, clockwise decreases)

Defective safety magnet.

Verify operation of safety magnet in the following

(mv Plus systems)

manner.

(A) Depress and hold pilot button.

(B) Verify open-circuit thermocouple voltage as de

scribed in previous step.

(C) Reconnect thermocouple to valve.

(D) Measure the Millivoltage between the solder button

on the base of the safety magnet, and the valve

body. If the mv reading is above 6mv for vented

appliances, or 8.5 mv for un-vented appliances, and

the safety magnet does not hold, replace the valve.

(E) If closed circuit mv reading is the same as the open

circuit reading, the coil is electrically open. Replace

the valve.

Defective Safety Magnet

Verify operation of safety magnet in the following

(Millivolt system)

manner.

(A) Remove all wires from the terminals of the main

operator.

(B) Measure the electrical voltage between the termi

nals TPTH and TP. If the voltage is above 110mv

and the safety magnet does not hold, replace the

valve.

Pilot orifice blocked.

Replace orifice with a new orifice of the exact size and

type.

Pilot drops out.

Wrong pilot orifice.

Replace the orifice with a new orifice supplied specifi

cally for the appliance and gas type in question.

No gas to main burner

Low gas pressure to appliance.

With the main burner functioning, adjust the inlet pres

sure regulator to supply gas to the appliance within the

design parameters of the appliance manufacturer.

(Typically 7”NG, 11”LPG).

Pilot not lit.

Light pilot and wait for thermo-generator to heat up

sufficiently to power the main operator. If pilot fails to

light, or hold, refer to above sections.

Control knob not in ON

Rotate OFF/PILOT/ON control knob to the ON position.

position.

Thermostat/wall switch

Thermostat not in ON position.

Turn thermostat ON, and adjust temperature control to

will not cycle main

call for heat.

burner.

System Checks

(continued)

Problem

Possible Cause

Solution

Advertising
This manual is related to the following products: