TDVN Series Direct Vent Gas Fireplace

20007636

Manifold pressure can be measured by using a 5/16”
I.D. hose in the right hand side of the valve and con-
necting a manometer. Two test gauge ports are acces-
sible for test gauge connection:
1. Tap on left side of the valve will give inlet supply

pressure.

2. Tap on the right side of the valve will give manifold

pressure.

Min. Input

Max. Input

33TDVP

13,000

18,000

36TDVP

14,500

20,000

39TDVP

16,500

22,000

FC107

SIT820

valve conversion

10/03

A

B

C

OFF

PILO

T

ON

FC107

Fig. 49 Remove mounting screws, pressure regulator tower
and diaphragm assembly, and discard.

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PILOT

ON

FC108

Fig. 50 Replace regulator.

Gas Supply Pressure (inches w.c.)

Minimum

Normal Maximum

LP (Propane)

10.8

11.0

14.0

Manifold Pressure (inches w.c.)

Nornal (HI)

Normal (Low)

LP (Propane)

10.0”

6.3”

Pressure ranges are: