plate

fixing

point

Plate

Figure 3

Discharge Direction:

The hood is

shipped ready for horizontal

discharge. To change to vertical

discharge move plate to the rear

side and ventilator (if supplied) to

the top side.

The plate and ventilator are held in

place by four nuts each, see also

Figures 3 and ,at page 9, Figure A

and Figure B.

Read also paragraph “Integral

Ventilator Installation” at pages

14-15 for further informations.
Note:

If an integral ventilator is

already supplied (HSB series hoods

only), remove it to allow installation

of hood to the wall/cabinet.

Assembly of the Transition:

The transition supplied with the

hood mounts to the top of the

hood, Figure 4.
1.

Fold outwards all six Tabs (HS

and HSB series only).

2.

Align mounting holes at base

of transition with mounting

holes on 1/2” flange located at

the top of the hood.

3.

Fasten transition to hood using

6 (4 mm x 9.5 mm) screws

(included with hood).

4.

Duct tape connection between

transition and hood.

5.

Remove tape holding damper

Transition

Top outlet

Tongue

Figure 4