BEFORE INSTALLING HOOD

1.

For the most efficient air flow

exhaust, use a straight run or

as few elbows as possible.
CAUTION:

Vent unit to

outside of building, only.

2.

Almost two people are

necessary for installation.

3.

The hood is fitted with Screws

and Drywall Anchors suitable

for most surfaces, consult a

Qualified Installer, check if

they perfectly fit with your

cabinet/wall.

4.

Do not use flex ducting.

5.

COLD WEATHER installations

should have an additional

backdraft damper installed to

minimize backward cold air

flow and a nonmetallic

thermal break to minimize

conduction of outside tem-

peratures as part of the

ductwork. The damper should

be on the cold air side of the

thermal break.

The break should be as close

as possible to where the

ducting enters the heated

portion of the house.

6.

Remote blowers require a five

wire installation.

7.

Make up air: Local building

codes may require the use of

Make-Up Air Systems when

using Ducted Ventilation

Systems greater than

specified CFM of air

movement.

The specified CFM varies

from locale to locale. Consult

your HVAC professional for

specific requirements in your

area.