From Control

Panel

Motor connector

VTN 420 or VTN 620

Wiring the HOOD with an
IntegralVentilator:

Warning:

Turn off electricity at

the service panel before wiring the

unit.
1.

Connect the Integral Ventilator

molex plug connector to the

connector present inside the

hood as shown in Figure 9 or
Figure 10

.

2.

Remove the j-box cover as

shown in Figure 11.

3.

Remove 1 of 2 knockouts and

install 1/2” conduit connector

in j-box.

4.

Run black, white, and green

wires (#14 AWG) in 1/2” conduit

from power supply to j-box.

5.

Connect black, white, and

green wires from power supply

to black, white, and green/

yellow wires in j-box

respectively.

6.

Close j-box cover.

Final installation steps
7.

Only HSB30 and HS30 Series

hoods: fit the side mould on the

right side, and fix it with 3

screws as shown in Figure 12.

8.

Replace filters as described in

the Care & Use section of this

manual.

Turn power on at service panel.