Texas Instruments TMS320F2802 User Manual

Page 114

Advertising
background image

t

d(IDLE−XCOL)

X1/X2

or XCLKIN

XCLKOUT

HALT

HALT

Wake-up Latency

Flushing Pipeline

t

d(WAKE−HALT)

(A)

(B)

(C)

(D)

Device

Status

(E)

(G)

(F)

PLL Lock-up Time

Normal

Execution

t

w(WAKE-GPIO)

t

p

GPIOn

Oscillator Start-up Time

TMS320F2809, TMS320F2808, TMS320F2806
TMS320F2802, TMS320F2801, TMS320C2802
TMS320C2801, TMS320F28016, TMS320F28015

SPRS230N – OCTOBER 2003 – REVISED MAY 2012

www.ti.com

Table 6-20. HALT Mode Timing Requirements

MIN

NOM

MAX

UNIT

t

w(WAKE-GPIO)

Pulse duration, GPIO wake-up signal

t

oscst

+ 2t

c(OSCCLK)

(1)

cycles

t

w(WAKE-XRS)

Pulse duration, XRS wakeup signal

t

oscst

+ 8t

c(OSCCLK)

cycles

(1)

See

Table 6-13

for an explanation of t

oscst

.

Table 6-21. HALT Mode Switching Characteristics

PARAMETER

MIN

TYP

MAX

UNIT

t

d(IDLE-XCOL)

Delay time, IDLE instruction executed to XCLKOUT low

32t

c(SCO)

45t

c(SCO)

cycles

t

p

PLL lock-up time

131072t

c(OSCCLK)

cycles

Delay time, PLL lock to program execution resume

1125t

c(SCO)

cycles

Wake up from flash

t

d(WAKE-HALT)

Flash module in sleep state

35t

c(SCO)

cycles

Wake up from SARAM

A.

IDLE instruction is executed to put the device into HALT mode.

B.

The PLL block responds to the HALT signal. SYSCLKOUT is held for approximately 32 cycles (if CLKINDIV = 0) or
64 cycles (if CLKINDIV = 1) before the oscillator is turned off and the CLKIN to the core is stopped. This delay
enables the CPU pipe and any other pending operations to flush properly.

C.

Clocks to the peripherals are turned off and the PLL is shut down. If a quartz crystal or ceramic resonator is used as
the clock source, the internal oscillator is shut down as well. The device is now in HALT mode and consumes
absolute minimum power.

D.

When the GPIOn pin (used to bring the device out of HALT) is driven low, the oscillator is turned on and the oscillator
wake-up sequence is initiated. The GPIO pin should be driven high only after the oscillator has stabilized. This
enables the provision of a clean clock signal during the PLL lock sequence. Since the falling edge of the GPIO pin
asynchronously begins the wakeup process, care should be taken to maintain a low noise environment prior to
entering and during HALT mode.

E.

Once the oscillator has stabilized, the PLL lock sequence is initiated, which takes 131,072 OSCCLK (X1/X2 or X1 or
XCLKIN) cycles. Note that these 131,072 clock cycles are applicable even when the PLL is disabled (that is, code
execution will be delayed by this duration even when the PLL is disabled).

F.

Clocks to the core and peripherals are enabled. The HALT mode is now exited. The device will respond to the
interrupt (if enabled), after a latency.

G.

Normal operation resumes.

Figure 6-16. HALT Wake-Up Using GPIOn

114

Electrical Specifications

Copyright © 2003–2012, Texas Instruments Incorporated

Submit Documentation Feedback

Product Folder Link(s):

TMS320F2809 TMS320F2808 TMS320F2806 TMS320F2802 TMS320F2801 TMS320C2802

TMS320C2801 TMS320F28016 TMS320F28015

Advertising