1

3䟻䟻䟻䟻 Changing the setting in SS (Synchro Scan) mode

Shutter mode AUTO, MANUAL, SS

Synchro scan setting

-- 1 SHUTTER -- <FILE A>

MODE

SS

15/1125H 1123/1125H (when 1080p/1080i is set)
10/750H 748/750H (when 720p is set)

SYNCHRO SCAN 1123/1125H

< MODE = SS >

(a) Changing the shutter speed setting

Move the “䊲” to SYNCHRO SCAN by pressing [MENU UP], [MENU DOWN] buttons.

Select the shutter speed by pressing [DATA UP], [DATA DOWN] buttons.

Move up and down

by pressing

MENU UP,DOWN

Select the desired

value by pressing

DATA UP,DOWN

DATA UP䠯

DATA DOWN䠯

15/1125H ࠉ1123/1125H

(when 1080p/1080i is set)

10/750H ࠉ748/750H

(when 720p is set)

Note:
The shutter speed can be set in every effective scanning line (1080/720).

(a) Changing the shutter speed

Move the “䊲” to MANU by pressing [MENU UP], [MENU DOWN] buttons.

Select the shutter speed by pressing [DATA UP], [DATA DOWN] buttons.

DATA UP䠯

DATA DOWN䠯

OFF 1/100s 1/125s 1/250s 1/500s 1/1000s 1/2000s 1/4000s

Note:
The shutter speed can be set in every effective scanning line (1080/720).
The figures of shutter speed in the menu screen are approximate. The accurate shutter speed is
calculated using the following mathematical formula.
Shutter speed (s) = 1/67433 (Hz) × n (n : 15 to 1123 (integral number)) (when 1080/59.94p and 1080/59.94i are set)

= 1/56250 (Hz) × n (n : 15 to 1123 (integral number)) (when 1080/50p and 1080/50i are set)

= 1/44955 (Hz) × n (n : 10 to 748 (integral number)) (when 720/59.94p is set)

= 1/37500 (Hz) × n (n : 10 to 748 (integral number)) (when 720/50p is set)