System interconnection wires and ground wire, Remote control wiring, Wiring diagram – Toshiba CARRIER RAV-SP420CT-UL User Manual

Page 21: Caution

Advertising
background image

– 20 –

Under Ceiling Type

Installation Manual

EN

Toshiba

„

System interconnection
Wires and Ground Wire

1. Strip wire ends.

System interconnection wire : 0.4” (10 mm).
Ground wire : 0.8” (20 mm)

2. Match wire colours with terminal numbers on indoor

and outdoor units’ terminal blocks and firmly screw
wires to the corresponding terminals.

3. Secure the ground wire with the ground screw.
4. Fix the wire with cord clamp.

Unit: in (mm)

CAUTION

• Firmly tighten the screws of the terminal block.

Keep the wire length as shown in figure below when it
is connected to the terminal block.

„

Remote Control Wiring

• Strip off approx. 0.4” (9 mm) the wire to be

connected.

• Non polarity, 2 x AWG20 wire is used for wiring of the

remote control.

„

Wiring Diagram

Single system

L

2

S

L

1

0.4” (10)

0.8” (20)

Connecting wire

Ground wire

System

interconnection wire

0.08”

(2 mm)

or less

A

B

A

B

Terminal block

Remote

control

unit

Terminal block for

remote control wiring

of indoor unit

Remote control wire

(Procured locally)

A B

L

1

L

1

L

2

L

2

S

S

208/230-1-60

Indoor unit

Outdoor

unit

Remote

control

Low voltage

High voltage

20-EN

+00EH99864801_00Ta.book Page 20 Tuesday, November 24, 2009 5:40 PM