Diagnosing led indicators – Transition Networks MIL-SW8T1GPA User Manual

Page 38

Advertising
background image

36

100

Ω

Category 5 cable for 100Mbps connections. Also be sure that the length of

any twisted-pair connection does not exceed 100 meters (328 feet). Gigabit port

should use Cat-5 or cat-5e cable for 1000Mbps connections. The length does not

exceed 100 meters.

Improper Network Topologies

It is important to make sure that have a valid network topology. Common topology

faults include excessive cable length and too many repeaters (hubs) between end

nodes. In addition, user should make sure that the network topology contains no

data path loops. Between any two ends nodes, there should be only one active

cabling path at any time. Data path loops will cause broadcast storms that will

severely impact the network performance.

Diagnosing LED Indicators

The switch can be easily monitored through panel indicators to assist in identifying

problems, which describes common problems may encounter and where can find

possible solutions.

If the power indicator does turn on when the power cord is plugged in, it may have a

problem with power outlet, or power cord. However, if the switch powers off after

running for a while check for loose power connections, power losses or surges at

power outlet. If the problem still cannot be solved, contact the local dealer for

assistance.