4 connecting stackmaster™tr to token ring network – Transition Networks STACKMASTER TR SMHB-TR-16 User Manual

Page 23

Advertising
background image

3.4

Connecting StackMaster™TR to Token Ring
Network

When NO connection to RI port:

• ALWAYS set Ring In switch to Active position.

NOTE: The INSERT LED should remain OFF.

When NO connection to RO port:

• ALWAYS set Ring Out switch to Active position.

NOTE: The NORMAL LED should remain OFF.

When adding passive hub to RI port:

• Connect cable between StackMaster™TR RI and

RO of the passive hub

Set Ring In switch to Passive position.

When adding passive hub to RO port:

• Connect cable between StackMaster™TR RO and

RI of the passive hub

Set Ring Out switch to Passive position.

When removing passive hub from RI port:

• Set Ring In switch to Active position

Disconnect cable between StackMaster™TR RI
and RO of the passive hub.

When removing passive hub from RO port: • Set “Ring Out” switch to Active position

Disconnect cable between StackMaster™TR RO
and RI of the passive hub.

When interfacing to other manufacturers’ hub: The StackMaster™TR 16-Port is fully tested for

interoperatbility with other manufacturers’
concentrators that are compliant with 802.5
standards. Ensure that the RI/RO configuration of
the manufacturers’ concentrators functions with
the StackMaster™TR 16-Port.