5. Maintenance

Maintenance of the StackMaster™TR 16-Port Stack is required only when
a StackMaster™TR 16-Port unit fails. Recovery of a failed
StackMaster™TR 16-Port unit requires fault isolation, using methods
provided in this section, and corrective action. Corrective action is taken
by simple procedures described in this section or by contacting
TRANSITION Networks Technical Support.

5.1 Fault Isolation

Use Table 5-1 for troubleshooting the StackMaster™TR 16-Port Stack.
Table 5-1 presents a list of faults and probable causes, presented in the
order of increasing probability, with suggested remedial action.

To use Table 5-1, locate the problem in the FAULT column. In the
PROBABLE CAUSE box next to the fault, find one or more probable
cause(s) associated with the fault. Examine each probable cause in turn,
beginning at the top. When the probable cause is identifed, take the
associated corrective action in the CORRECTIVE ACTION column.

FAULT

PROBABLE CAUSE

CORRECTIVE ACTION

Unit POWER LED

Disconnected

Connect power cord.

not illuminated

power cord.

Improperly

For 110-120V use,

installed fuse.

fuse should read 110-
120V in upright position;
for 210-240V use, fuse
should read 210-240V in
upright position.

Fuse failure.

Replace fuse. (See 5.3.1.)

Power supply

Contact Technical

failure.

Support.
1-800-260-1312