3.5 Connecting Units to Power

The StackMaster™TR 16-Port Stack is connected to power by connecting
each of the StackMaster™TR 16-Port Units to power.

NOTE: Connect StackMaster™TR 16-Port Units from bottom to top.

To connect the StackMaster™TR 16-Port Stack to power:

1.

At StackMaster™TR 16-Port Unit back, locate the Unit power
receptacle and associated fuse.

NOTE: Fuse must be installed at correct setting for power source voltage
before connecting to AC outlet.

2.

Verify that fuse is installed at correct setting for power source
voltage.

NOTE: The installed fuse rating is indicated by the reading at lower right
corner of fuse holder.

If not installed at correct setting for power source voltage:

Carefully open fuse receptacle, using a small flat blade
screwdriver.

Rotate fuse holder 180° to the correct rating orientation.

Install fuse holder in correct rating orientation.

Close fuse receptacle.

3.

Plug unit end (female) of power cord into StackMaster™TR 16-
Port Unit power receptacle.

4.

Plug outlet end (male) of power cord into correct voltage AC wall
socket.

5.

At StackMaster™TR 16-Port Unit front, verify that POWER LED is
illuminated.

6.

Repeat steps 1 through 5 until all StackMaster™TR 16-Port Units
have been powered.

StackMasterTR

3-6

110-120

110-120

220-240

220-240

110-120 Orientation

220-240 Orientation

Fuse Holder

Fuse Holder

Advertising