Toshiba LF502 User Manual

Page 2

Advertising
background image

TIC-LF502A

2

Required straight pipe length:

10D minimum on upstream side and

5D minimum on downstream side

Note: D is a nominal meter size.

Fluid conductivity: 100µS/cm minimum

Fluid temperature: 32 to 131 °F (0 to 55 °C )

Ambient temperature: 14 to 122 °F (-10 to 50 °C )

Dimensions and Weights: See figures 3 to 5.

Power supply:

100 to 120 Vac (80 to 132 Vac), 50/60Hz

Power consumption: 50VA (30W) or less

Model LF502 Detector

Meter sizes: 6” (150 mm ), 8” (200 mm ), 10” (250

mm ), 12” (300 mm ), 14” (350 mm ), 16” (400

mm ), 20” (500 mm ), 24”(600 mm )

Fluid pressure:

0 psi or 0 bar (0 MPa) to the pressure limited by

flange standard
(fully-filled condition)

Connection flange standards:

ANSI 150, JIS 10K

Structure:

IP67 and NEMA 4X Watertight (std. )

IP68 and NEMA 6P Submersible (opt.)

Coating: Phthalic acid resin coating, pearl-gray

colored (standard for watertight type) or black tar

epoxy (option for watertight type and specified

exclusively for submersible type)

Principal materials:

Case — carbon steel
Measuring pipe — 304 stainless steel
Linings
— The following are the standards:

Meter size

Standard specification

6” to 16” (150 to 400mm )

EPDM rubber

20” & 24” (500 & 600mm )

Chloroprene rubber

Electrodes — 316L stainless steel (std.)
Grounding rings —
The following are the

standards.

Meter size

Standard specification

6” to 16” (150 to 400mm )

316 stainless steel

20” & 24” (500 & 600mm )

304 stainless steel

See Table 1 for optional materials and other

related information.

Coating: phthalic acid resin coating (std.),
Pearl-gray colored

Cable connection port:

Cable glands: Provided as standard, R(PT) 1/2

male screw.

Applicable diameter: 0.433 to 0.512 inch (11

to 13mm )

Model LF232*F converter

Input signals

Analog signal the voltage signal from detector,

proportional to process flow rate.

Digital input DI (opt.)
(added when 9

th

digit of specification code is ”3”)

Voltage level: High level 20 to 30 V dc

Low level 2 V dc or less

Input resistance: 2.7 k

Number of inputs: 2 points (DI1 and DI2)

DI functions:

For digital input function, either of the following
functions can be selected.

• Range switching

One Digital Input is used: switching between large
and small ranges of forward/reverse, 2-range
measurement.
Two Digital Inputs are used: switching between
ranges of single direction, 4-range measurement.

• Totalizer control input
Totalizer Start/Stop control or Reset/Start
•Output hold input

Fixed with set value for current output and pulse
output (loop check)

• Zero adjustment

Starts zero adjustment (on-stream at zero flow rate)
when DI voltage level goes low after remaining
high for 10 to 20 seconds.

Output signals

Current output:

4–20mAdc (load resistance 0 to 1K

Ω)

Digital output (DO) — One point (std.) and three

more point is optionally available as follows.

Digital output DO1 (std.):

Output type: Transistor open collector

Number of outputs: One point

Output capacity : 30Vdc, 200mA maximum

Digital output DO2DO4 (opt.)

(Added when 9

th

digit of specification code is “3”)

Out put type: Solidstate relay output (non polarity)

Number of outputs: 3 points

Output capacity: 150Vdc, 150mA maximum or

150Vac (peak to peak),

100mA maximum

DO functions—Four digital output function, either of

the following functions can be selected.

• Totalizer pulse output

DO1 or DO2 can be selected (Forward direction

pulse and reverse direction pulse can be assigned

Advertising