Maintenance timeout skip – Toro 12 User Manual

Page 62

Advertising
background image

56

1. Turn the Function dial to the blank position, located

between Flow and Reports.

MAINTENANCE TIMEOUT
Skip

2. Turn the Lower Line dial to Edit.

3. Turn the Upper Line dial one click.

4. Turn the Lower Line dial to ON.

5. Turn the Upper Line dial to highlight Time.

6. Turn the Lower Line dial to set timeout duration (0.5–8.0 hours).

Using the Maintenance Timeout Function

The MaintenanceTimeout feature enables a time period ranging

from 0.5 to 8.0 hours to be set, then selectedas required. During

the timeout period, the leak detection function is disabled and

the normally-closed master valve is energized. A typical use of

the Maintenance Timout function would be to facilitate quick-

coupler irrigation.