Step 6: Electrical
Requirements, Connection &
Grounding

Prior to servicing appliance, always disconnect
appliance electrical supply cord, if so equipped, from
wall receptacle. If appliance is hard-wired to power
supply, disconnect power to unit by turning off the
proper circuit breaker or disconnecting the proper fuse.
Lock service panel to prevent power from being turned
ON accidentally.

Dual Fuel range models can be connected or hardwired to
the power supply as described on page 14.

A neutral supply wire must be provided from the power
source (breaker/fuse panel) because critical range
components, including the surface burner spark
reignition module, require 120 VAC to operate safely
and properly.

WARNING

An improper 120/ 240 VAC power supply will
cause malfunction, damage to this appliance,
and possibly create a condition of shock hazard.

Figure 8: Location of Gas Supply Inlet Connection

on 30” and 36” Ranges

Figure 9: Location of Gas Supply Inlet Connection on 48”

Ranges

A

Chart B: Electrical Supply Circuit Requirements

MODEL

TYPE

VOLTAGE

CIRCUIT

RATING

FREQUENCY

PHASE

30”

240/208 VAC

35 Amps

60 Hz.

Single

36”

240/208 VAC

35 Amps

60 Hz.

Single

48”

240/208 VAC

50 Amps

60 Hz.

Single