Important notes, Step 2: cabinet preparation, Caution – Thermador PRO-HARMONYTM PRD30 User Manual

Page 6: Note

Advertising
background image

English 4

Step 2: Cabinet Preparation

1.

The range is a free standing unit. If the unit is to be
placed adjacent to cabinets, the clearances shown in
Figure 1 are required. The same clearances apply to
island installations, except for the overhead cabinets,
which must have a space wide enough to accept the
flared island hood, as indicated in Figure 1.

2.

These ranges may be recessed into the cabinets
beyond the edge of the front face of the oven (See
Figure 2 and Figure 3b).

CAUTION

In these installations, the door and cabinet can
cause a pinching hazard.

3.

The gas and electrical supply should be within the
zones shown in Figure 3a.

Note:
The maximum depth of over head cabinets installed on
either side of the hood is 13".

A 36-inch minimum clearance is required between the top
of the cooking surface and the bottom of an unprotected
cabinet. A 30-inch clearance can be used when the bottom
of the wood or metal cabinet is protected by not less than
1/4 inch of a flame retardant material covered with not less
than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick
stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020
inch (0.5 mm) thick copper. Flame retardant materials bear
the following mark:

UNDERWRITERS LABORATORIES INC. CLASSIFIED
MINERAL AND FIBER BOARDS SURFACE BURNING
CHARACTERISTICS

Followed by the flame spread and smoke ratings. These
designations are shown as “FHC (FIame Spread/Smoke
Developed).” Materials with “O” flame spread ratings are
flame retardant. Local codes may allow other flame spread
ratings.

4.

Any openings in the wall behind the range and in the
floor under the range must be sealed.

5.

When there is less than a 12" horizontal clearance

between combustible material

and the back edge of

Range

Width

Range Top

Configuration

Ventilation Options

30"

4 burners

30” or 36” Pro Wall Hood

30” or 36” Custom Insert w/ optional blower

42” Island Hood w/ optional blower

36"

4 burners with griddle

36” or 42” Pro Wall Hood

36” Custom Insert w/ optional blower

42” or 48” Island Hood w/ optional blower

6 burners

48"

6 burners with griddle

48” or 54” Pro Wall Hood**

48” Custom Insert w/ optional blower

Important Notes:

• It is recommended that a Thermador Professional wall or island hood or custom insert is used with Thermador

Professional Ranges.

• The HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation

solutions for these ranges. The PH Professional Series Wall Hoods are also a viable option, however the 27” depth of
the PH series may not be suitable to all applications.

• Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and

Accessories.

• For high output gas ranges (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is

recommended. If the range has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity
may be required for longer duct runs.

• For island applications, it is recommended to use a hood width that exceeds the width of the range by 6” (overlapping

the range by a minimum of 3” on each end).

• **Not all 48” Pro Wall Hood models can accommodate a 1,300 CFM blower option.

• CFM = “cubic feet per minute” (standard blower capacity rating).

Δ

Advertising
This manual is related to the following products: