English 5

the range above the cooking surface, a Thermador
Low Back or Pot and Pan Shelf must be installed. (See

Figure 2). When clearance to combustible material

is over 12", a Thermador Flush Island Trim may be
used. Figure 2 indicates the space required for each
type of backguard.

6.

Always keep appliance area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.

7.

Do not obstruct the flow of combustion and ventilation
air to the unit.

8.

A five (5) inch minimum clearance is needed when the
range is installed beside a combustible side wall.

A

s defined in the “National Fuel Gas Code” (ANSI

Z223.1, Current Edition).

Δ

Δ

Figure 1: Cabinet Clearances

For Electrical and Gas Supply Zone, see
Figure 3A.

Cooking

Surface

,

CAUTION:

See Figure 2
36" Min. to
combustible

material

Ð

,

from cooking

surface

as defined in the “National Fuel Gas Code” (ANSI Z223.1,

Current Edition).*The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.

Range width

30", 36" or 48"

30" or 36" Wide Hood
36" or 42" for Island

}

For 30" Ranges

36" or 42" Wide Hood
42" or 48" for Island

}

For 36" Ranges

48", 54" or 60" Wide Hood
54" for Island

}

For 48" Ranges

Min. Distance Between Overhead Cabinets

of Combustible Material

30" Range – 30"
36" Range – 36"
48" Range – 48"

13" Max.

Cabinet

Depth

}

5" Min. to
combustible
side wall
material ,
(both sides)

18"

Min.

*35-7/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.

30" minimum from bottom of

overhead Hood to cooking

surface (36" min. if hood

contains combustible

materials )