Safety instructions, Warning, Important – Thermador PRO-HARMONYTM PRD30 User Manual

Page 4: Note, Important installation information, Gas type verification, Important safety instructions

Advertising
background image

English 2

Safety Instructions

Important Safety Instructions

READ AND SAVE THESE INSTRUCTIONS

APPROVED FOR ALL RESIDENTIAL APPLIANCES

FOR RESIDENTIAL USE ONLY

IMPORTANT: Save these Instructions for the Local
Electrical and Gas Inspectors' use.

INSTALLER: Please leave these Instructions with this unit
for the owner.

OWNER: Please retain these instructions for future
reference.

WARNING

Disconnect power before installing. Before
turning power ON, be sure that all controls are in
the OFF position.

Important:

Local codes vary. Installation, gas connections and
grounding must comply with all applicable codes.

WARNING:

Do not use a flame of any kind to check for gas
leaks.

Disconnect power before installing. Before turning power
ON, be sure that all controls are in the OFF position.

Note:
This Range is NOT designed for installation in
manufactured (mobile) homes or for installation in
Recreational Park Trailers.

Do Not install this range outdoors.

Important Installation Information

GAS type verification

Verify the type of gas supplied to the location. Ensure that
the appliance is connected to the type of gas for which it is
certified. All models are certified for use with natural gas.
Field conversion of the appliance for use with propane gas
supply will require a conversion kit.

WARNING

:

To avoid possible burn or fire hazard, a
backguard designed specifically for this range
must be installed whenever the range is used.

Refer to “Chart C: Backguard Kit Model Numbers” on
page 17
, for the correct backguard models that are
designed for this range. After selecting the correct
backguard, the range must be installed properly, using the
minimum clearances to combustible surfaces specified in
the Cabinet Preparation instructions on page 4.

Important:

A backguard must be utilized when there is less than a
12" horizontal clearance between combustible

materials and the back edge of the range. A
Thermador backguard must be ordered separately and
installed at the rear of the range. A Low Back is
supplied with the 30“ model, and all other models are
supplied with a Flush Island Trim. For island
installations and other installations with more than 12"
clearance, an optional stainless steel Island Trim is
available to cover the backguard mounting flanges.

Verify that the appliance is correct for the type of gas
being provided. Refer to “Step 5: Gas Requirements
and Hookup” on page 12
before proceeding with the
installation.

This appliance has been tested in accordance with ANSI
Z21.1, Standard for Household Cooking Appliances (USA)
and in accordance with CAN 1.1-M81 Domestic Gas
Ranges (Canadian).

It is strongly recommended that this appliance be installed
in conjunction with a suitable overhead vent hood. (See
“Step 1: Ventilation Requirements” on page 3.
) Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.

Advertising
This manual is related to the following products: