Taurus Group 60 User Manual

Page 25

Advertising
background image

Turbomachinery Package Specification

Taurus

60 Compressor Set and Mechanical Drive

Variable Frequency Drive (cont.)

Power Factor

0.96

Efficiency 98%
Minimum/Maximum Operating Temperature

-10 to 40°C (14 to 104°F)

Heat Rejection

- 380 to 460 VAC Input

1780 watts

Input Fuse Rating

225 amp

Approximate Measurements

- Height

85 cm (33.5 in.)

- Width

42 cm (16.6 in.)

- Depth

32 cm (12.7 in.)

Approximate Weight

70 kg (155 lb)

Starter Motor

Motor Type

Squirrel-cage Induction

Motor Voltage Rating

380 AC, (0 to 133 Hz)

Power

56 kW (75 hp)

Operating Speed

0 to 4000 rpm

Maximum Breakaway Amperage

205 amps

Maximum Breakaway Torque

472 N-m (348 ft-lb)

Minimum/Maximum Operating Temperature

-25 to 60°C (-13 to 140°F)

Space Heater Voltage

120 VAC, 60 Hz
240 VAC, 50 Hz

Approximate Measurements

- Length

75 cm (29.4 in.)

- Diameter

45.7 cm (18 in.)

Approximate Weight

- AC Starter Motor Assembly

370 kg (820 lb)

Power Wiring

VFD to Starter Motors Power Cable Length

38 m (123 ft), See Note (b)

Solar’s Applicable Engineering Specifications

ES 1593

Guidelines for NEC Compliance of Solar Product Lines: Class I, Group D, Division 1 and
Division 2

ES 1762

Standards and Practices for Electrical Systems For Gas Turbine Packages Installed in
Hazardous Areas (CENELEC Standards)

Solar’s Applicable Product Information Letters

PIL 149

Direct-drive AC Start Systems

Notes:

(a)

Feeder circuits exceeding this limit require the use of an isolation transformer, line reactor, or
other means of adding similar impedance to limit fault current.

(b)

Longer cable runs may require an onskid marshalling box and/or output line reactor.

© 2009 Solar Turbines Incorporated. All rights reserved.

TPS60CSMD/309

24