background image

Turbomachinery Package Specification

Taurus

60 Compressor Set and Mechanical Drive

Construction Materials
Prefilter/Barrier

Carbon Steel (Standard); 316L Stainless Steel
(Optional)

Insect Screen (Optional)

316L Stainless Steel

Self Cleaning Barriers

Carbon Steel (Standard); 316L Stainless Steel
(Optional)

Marine High Velocity Air Cleaner

316L Stainless Steel

Offshore / Coastal Medium Velocity Type Air
Filter

316L Stainless Steel (Standard), Carbon Steel
(Optional for mild coastal environments)

Air Inlet Silencer

Carbon Steel (Standard); 316L Stainless Steel
(Optional)

Air Inlet Support Structure

Carbon Steel (Standard)

Solar’s Applicable Product Information Letters
PIL 054

OSHA Noise Requirements

PIL 178

Salt Ingress Protection for Gas Turbines

Notes

:

(a)

The particle size in the compressed air stream should not exceed 10μm. Since it is
impractical to remove 100% of all particles larger than 10μm, this is defined as ß10 > 100, or
99% efficient. Oil or hydrocarbon content should not exceed 1 ppm. The dew point at line
pressure shall be at least 6°C (10°F) below the minimum temperature to which any part of
the air system is exposed or between 1.6°C and 60°C (35°F and 140°F). Air should be free
of all corrosive contaminants, hazardous gases, flammables, and toxics.

© 2009 Solar Turbines Incorporated. All rights reserved.