Taurus Group 60 User Manual

Page 44

Advertising
background image

Turbomachinery Package Specification

Taurus

60 Compressor Set and Mechanical Drive

Offskid Control Console Dimensions

One-Bay Control Console

Height

2286 mm (90 in.)

Width

914 mm (36 in.)

Depth

800 mm (32 in.)

Approximate Weight

570 kg (1250 lb)

Two-Bay Control Console

Height

2286 mm (90 in.)

Width

1448 mm (57 in.)

Depth

800 mm (32 in.)

Approximate Weight

680 kg (1500 lb)

Supervisory Interface Modules

ControlNet 1.5

Cables RG-6U

Coaxial

Maximum Cable Length

1000 m (3300 ft)

Transmission Protocol

Common Industrial Protocol (CIP)

Transmission Speed

5 Mbps

Ethernet

Cables 10BaseT
Network Length

100 m (330 ft) To Nearest Hub

Transmission Protocol

CIP Protocol with TCP/IP

Transmission Speed

10 Mbps

Data Highway Plus

Cables

DH+ Twisted Pair

Maximum Cable Length

3000 m (10,000 ft)

Transmission Protocol

CIP or DF1 Protocol

Transmission Speed

57.6 bps

Modbus

Cables

RS232C, RS422, or RS485

Cable Length

RS232C: 15 m (50 ft)
RS422 and RS485: 1200 m (4000 ft)

Transmission Protocol

Subset of Modbus RTU Protocol

Package End Devices

Transmitters 4-20

mA

Switches 0-24VDC
Thermocouples Type

K

RTDs

100 ohm Platinum

Proximitors 3300XL

Solar’s Applicable Engineering Specifications

ES 9-56

Fusion Welding

ES 1593

Guidelines for NEC Compliance of Solar Product Lines: Class I, Group D, Division 1
and Division 2

ES 1762

Standards and Practices for Electrical Systems for Gas Turbine Packages Installed In
Hazardous Areas (CENELEC/IEC Standards – European ATEX Directive 94/9/EC)

ES 2231

Standards and Practices for The Design and Installation of Cable Channels and TC
Rated Cables Installed In Class 1, Division 2 Hazardous Areas

© 2009 Solar Turbines Incorporated. All rights reserved.

TPS60CSMD/309

43