IPT2010-SDC

IPT2010-SDC Programming

88

Strata CIX and CTX IPT/DKT Telephone 08/07

IPT Initialization

The IPT2010-SDC has a fourth initialization option (FB4). ACO Default.

1. Press

3

+

6

+

9

+

Hold

(simultaneously).

2. Press

Vol

s then press Hold.

3. Press

FB04

. Revert to factory default ACO settings or Use the saved ACO

settings. (LED On = revert to factory default, LED OFF = use the saved ACO
settings). This will set all the IPT2010-SDC program options to factory default
values.

IPT2010-SDC Headset Transmit Level Adjustment

The IPT2010-SDC headset transmit level for ACO and IPT operation are set by
programming from the station.

1. Press

3

+

6

+

9

+

Hold

(simultaneously).

2. Press

#

then press Hold.

3. Set the headset transmit level using FB1, FB2 and FB3 as shown in the table

below.

4. Press Hold again.

Headset Transmit Levels

Transmit Level

FB1

FB2

FB3

IPT Level

ACO Level

Max. (louder)

OFF

OFF

OFF

+12 dB4

+8 dB

ON

OFF

OFF

+8 dB

+8 dB

OFF

ON

OFF

+4 dB

+4 dB

(Default)

ON

ON

OFF

0 dB

0 dB

OFF

OFF

ON

-4 dB

-4 dB

ON

OFF

ON

-8 dB

-7 dB

OFF

ON

ON

-12 dB

-7 dB

Min. (softer)

ON

ON

ON

-16 dB

-7 dB