Local co line circuit quick test, Local co line circuit quick – Toshiba CTX IPT/DKT User Manual

Page 108

Advertising
background image

IPT2010-SDC

Local CO Line Connection

90

Strata CIX and CTX IPT/DKT Telephone 08/07

Local CO Line Circuit Quick Test

This procedure is a quick test to verify the CO Line connection and correct IPT2010-
SDC ACO operation. In normal operation the ACO indicator is dark when the ACO
line is not in use, red when the ACO is used by another station, and green when the
ACO is in use at this station. The ACO indictor that is lit a steady red, when the ACO
is not in use, indicates no CO Line connection or a faulty CO Line circuit.

Note

The IPT2010-SDC does not require a LAN connection for this test.

1. Apply power to the IPT2010-SDC (POE or local AC adapter). The ACO button

will LED will be red.

2. Plug in the local CO Line connection. A functional line will cause the ACO

indicator to go dark.

3. Lift the handset then, press the ACO button. Verify that the ACO indicator lights

green and dial tone is heard.

4. Dial a local telephone number. Verify two-way speech.

5. Place the handset in the IPT2010-SDC and verify that the ACO indicator goes

dark.

Advertising