LED Diagnostic Indicators

The Switch status can be easily monitored through panel indicators. If the

power indicator does not light when the power cord is plugged in, you

may have a problem with AC power outlet or power cord. However, if the

Switch powers off once running, Check for loose power connections,

power losses, or surges at the AC power outlet. If you still cannot resolve

the problem, contact your local dealer for assistance.

Improper Network Topologies

RJ-45 ports: Use unshielded twisted-pair (UTP) or shielded twisted-pair

(STP) cable for RJ-45 connections: Category 3, 5e or 6 cable for 10Mbps

or Category 5e and 6 cable for 100Mbps connections. Ensure that the

length of any twisted-pair connection does not exceed 100 meters ( 328

feet ).

100Base-FX fiber port: The Multi-Mode Fiber connector type must use

50/125 or 62.5/125µm MM fiber cable. You can connect two devices over

a distance of up to 2km. However, the Single Mode Fiber connector must

use 9/125µm Single Mode fiber cable. You can connect two devices up

to 30 kilometers apart in full duplex operation, utlilizing Single Mode

format.