Search and Close Call Options

On

The scanner automatically applies repeater reverse to

detected transmissions. If the scanner detects the
transmission on the output frequency, it beeps, REPEATER
FIND

appears, and it remains on the output frequency until

transmissions end. If it does not detect a transmission on
the output frequency, it remains on the original frequency.

Off

The scanner does not try to find the output frequency.

Setting the Maximum Auto Store
Value

Srch/CloCall Opt

E

Max Auto Store

E

This value sets how many hits the scanner will
automatically store when it is in either Search and Store
or Close Call Auto Store mode.

Use the number keys to enter a value from 1 - 256, then
press E.

When the scanner reaches the maximum number of hits
you set, it stops the auto-store operation.

Setting the Modulation Type

Srch/CloCall Opt

E

Set Modulation

E

This setting controls the modulation type used for quick
search and Close Call operations. Select your setting, then
press E.

Auto

Uses the default setting for the current frequency

(see the table at the front of the manual)

AM

Uses AM (amplitude modulation)

FM

Uses FM (frequency modulation)

NFM

Uses narrowband FM