Viking VCWB300 User Manual

Page 13

Advertising
background image

DIAGNOSTIC CHECK POINTS

(Rfer to Wiring Schematic on Page 19)

Number DescriptionA

E1

Display Board Send

1 +5Vdc
2 data

signals

3 ground


E2

Touch switch inputs (with switches connected), typical

1 +5VDC
2

Ground Common for measurements on E2

3 Not

connected

4

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.

5

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.

6

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.

7 +5Vdc
8

Ground Common for measurements on E2.

9 Not

connected.

10

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.

11

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.

12

When button is touched +4Vdc to +5Vdc, otherwise less than +1Vdc.


E3

Outputs and line voltage inputs (loads connected) typical.

1

Showroom switch off = 0V, on = 120VAC

2 – 7

Not connected.

8

Door switch open = 0V, closed = 120VAC.

9

When Zone* is being cooled or service mode = 115 VAC , off = 0V

10

When Zone* is being cooled or service mode = 115 VAC , off = 0V

11

When Zone* is being cooled or service mode = 115 VAC , off = 0V

12

When zone** is being cooled or service mode = 115 VAC , off = 0V

13

When zone** is being cooled or service mode = 115 VAC , off = 0V

14

When zone** is being cooled or service mode = 115 VAC , off = 0V

15

When zone* lights to be on = 115 VAC , off = 0V

16

Power line neutral. Common for all E3 measurements.

* E3 pin 9 Solenoid #1 / pin 10 Solenoid #2 / pin 11 Solenoid #3
** E3 pin 12 Evap. Fan #1 / pin 13 Evap. Fan #2 / pin 12 Evap. Fan #3.

NOTE: All wiring controlling Fan #3, Sol #3, and both #3 Thermisters have Black strips.

All wiring controlling Fan #2, Sol #2 and both #2 Thermisters have Red strips.

All wiring controlling Fan #1, Sol #1 and both #1 Thermisters have White strips.

14