TROUBLESHOOTING GUIDE (con’t)

PROBLEM POSSIBLE CAUSE CORRECTION

5. Door Ajar

a. (See page 21)


6. Evaporator Thermistor

Fault.

a. (See page 17)

7. Condenser Air / Con-

denser Fan Fault.

a. (See page 22)

8.

Check

Thermistors

a. (See E4 checks, page 15)


9. Refrigerant Valve

Solenoid Fault

a. Solenoid disconnected

a. (See solenoid checks page 14)

or

malfunctioning.



10. Sealed System leak or

Restriction

a. (See compressor data page 16)


C. Product Temper-

1. Compartment

a. Check thermistor ohms (See

ature is actually 10

°

Thermistor Fault

page 15 and 17). Replace if

or more colder than

defective.

If

thermistors

are

displayed

OK,

replace

control

board.

temperature.

D. Cold Temper-

1. Control Set too cold

a. Check set-points. Adjust set-

ature in all Wine

point

Warmer.

Storage
Compartments

2. Door Ajar
a. Wine rack obstruction

a. Adjust wine rack

b. Door out of adjustment

b. See door adjustment page 13.

c. Door or cabinet hinge

c. Check hinges. Replace if

problem.

defective.

3. Control Set too Cold

a. Check set-points. Adjust set-

points

WARMER.

4. Room Temperature

Below Set-Point

a. Instruct Customer

E Cold Temperatures 1. Door Ajar

In only one Wine

a. Wine rack Obstruction

a. Adjust wine rack.

Storage Compartment b. Door out of adjustment

b. See door adjustment

procedures (See page 11) in

this

manual.


23

Advertising