3.

Hinges and Lock Keeper

a.

Refer to Figure 2-3. To remove the hinge base from
the cabinet fascia, unscrew the three phillips type
machine screws.

Figure 2-3

b. To remove lock keeper (“D” shaped metal stamping

for lock bolt), use a 5/16” open end wrench. Remove
the two #10-32 screws attaching keeper to fascia.
Reverse procedure to reinstall. Refer to Figure 2-4.

Figure 2-4

Lock Keeper

D. Rehingeability (One & Two Section Long Door

Cabinet)

1.

Remove door from cabinet by opening it about 90

°

and lifting it from it’s supporting brackets (as
mentioned on page 7).

2.

Carefully pry the hinge barrel cover from hinge barrel
(Fig 2-5).

Figure 2-5

3.

Remove hinge barrels from door, turn them upside
down and replace on door (Figure 2-6).

Figure 2-6