Velodyne Acoustics HDL-64E S2 User Manual

Page 25

Advertising
background image

Version=dec2hex(value(s-1))
Temperature=value(s-2)
GPS=value(s-3)
speed=single(value(s-48))+single(value(s-47))*256
Fov_start=single(value(s-46))+single(value(s-45))*256
Fov_end=single(value(s-44))+single(value(s-43))*256
warning=value(s-13)
power=value(s-12)
Humidity=value(s-58)

% Done with Unit Parameters.

Reading Calibration and Sensor Parameter Data
Laser ID # is a 1 byte integer. Most of the output calibration data are 2 byte signed integers, except minimum and maximum intensity, which
use 1 byte each. See Appendix E for more information.

Status Type

ASCII Value Interpretation and Scaling

Vertical correction

Divide by 100 for mm

Rotational angle correction

Divide by 100 for mm

Distance far correction

mm

Distance correction X

mm

Distance correction Y

mm

Vertical offset correction

mm

Horizontal offset correction

mm

Focal distance

mm

Focal slope

Divide by 10 to scale

Minimum intensity

No scaling

Maximum intensity

No scaling

[ 22 ]

HDL-64E S2 and S2.1 User’s Manual

aPPendix d: MatLaB saMPLe code